11.1 SOFTWARE UPGRADE PROCEDURE
CHAPTER 11: SOFTWARE UPGRADE PROCEDURE
FIGURE A FIGURE B
1) Copy the Picard software onto the USB drive (Figure A).
2) Turn on the power to the Ascent Trainer, wait until the standard display picture has been come up (Figure B).
3) Enter Manager Mode by pressing ENTER, 1, 0, 0, 1, ENTER on the lower keypad.
4) Record the Accumulated Mileage, Accumulated Time, and Serial Number. note: The information can be lost during the update procedure
and should be recorded so that the information can be entered into the newly updated console.
5) Press the HOME key to return to the standard display picture.
6) Enter Update manager by pressing ENTER, 3, 0, 0, 4, ENTER on the lower keypad.
7) Insert the USB Drive into the USB port in the console (Figure C).
8) Press the Settings key on the screen. Then select the update source (Figure D).
9) Press the Clear Current Updates Key on the screen (Figure E).
10) Press the Available Updates key on the screen (Figure F).
FIGURE C FIGURE D
FIGURE E FIGURE F