Matrix E7x Dokumentacja Strona 39: High or no resistance
35
High or no resistance
possible causes:
1) The console cable is damaged or not properly plugged in.
2) The UCB is damaged.
3) The Generator is damaged.
4) The LCB is damaged.
SOLUTION:
1) Check the console cable connections at the UCB and LCB.
2) Check if the generator is outputting variable power:
a. Insert the probes from a multi-meter into the black and red wires on the generator wire harness connector (Figure A).
b. When pedaling, the output voltage from the generator should vary depending on the RPM. The generator should output 120 VAC at 94
RPM.
3) If the generator does not have variable power, replace the generator.
4) If the generator does have variable power, replace the LCB.
figure a
8.8 troubleshooting - resistance issues
chapter 8: troubleshooting
Plik PDF · ·
Pytania o Matrix E7x
Nie ma jeszcze pytań o tę instrukcję. Zadaj pierwsze.
Powiązane produkty i podręczniki dla Rowerki do ćwiczeń Matrix E7x
- Rowerki do ćwiczeń Matrix U3x Instrukcja Użytkownika
(42 strony) - Rowerki do ćwiczeń Matrix R7xi Instrukcja Obsługi
(137 stron) - Rowerki do ćwiczeń Matrix E5x Dokumentacja
(74 strony)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90